Keysight E4982A LCR Meter E4982A-050:1 MHz to 500 MHz
Keysight E4982A LCR Meter E4982A-050:1 MHz to 500 MHz
E4982A-050:1 MHz to 500 MHz
E4982A-100:1 MHz to 1 GHz
E4982A-300:1 MHz to 3 GHz
E4982A-030:1 MHz to 300 MHz
Key features
Unparalleled measurement speed and repeatability
▶0.9 msec (measurement time mode 1)
▶2.1 msec (measurement time mode 2)
▶3.7 msec (measurement time mode 3)
▶Low variation for repeatability
Excellent accuracy and wide impedance range
▶11 parameters: |Z|, |Y|, L, C, R, X, G, B, D, Q, ø
▶Measurement range from 0.14 Ω to 4.8 kΩ (within 10% accuracy)
▶0.8% basic accuracy
▶Sophisticated calibration/compensation method with calibration wizard function
System Integration Capability with 4287A compatibility
▶SCPI commands
▶GPIB, LAN, USB, Handler interface
▶Cable extension and small test head (the same size as the 4287A)
▶Multi-function comparator
▶Contact check using DCR measurement function
New functions which are not in 4287A
▶List measurement up to 201 points/table, table and plot format
▶User defined function keys/parameters
▶Undo recall/preset
▶Context sensitive embedded help
The E4982A LCR meter provides the best performance for passive component manufacturing such as SMD inductors and EMI filters where impedance testing at high frequencies (1 MHz to 300 MHz / 500 MHz / 1 GHz / 3 GHz) is required.
Highlights
New Standard for High-Speed Component Tests
Keysight E4982A LCR meter provides the best performance for the passive component manufacturing such as SMD inductors and EMI filters, where impedance testing at high frequencies is required. Not only for the manufacturing, E4982A can also be utilized for R&D, quality assurance with the powerful functions such as list measurements. By offering the unparalleled measurement speed and repeatability with excellent accuracy and impedance range, E4982A is the new standard for high speed component tests.
Frequency
▶Four frequency options: 1 MHz to 300 MHz / 500 MHz / 1 GHz / 3 GHz, upgradeable
Measurement Time
▶High-speed measurement: 0.9 ms (Mode 1), 2.1 ms (Mode 2), 3.7 ms (Mode 3)
Basic Accuracy And Impedance Range
▶0.8% basic accuracy with unparalleled measurement repeatability
▶Wide impedance measurements range from 140 mΩ to 4.8 kΩ
More Features
▶Compatible SCPI commands and Handler interface with the 4287A LCR meter
▶Small test head (the same size as 4287A)
▶List measurement
▶Versatile PC connectivity (GPIB, LAN, and USB)





Recently Posted
-
Software-Defined Instruments: How USB Spectrum Analyzers Are Changing the RF Testing Industry
August 17, 20261. The Benchtop Instrument That Would Not Fit in a Carry-OnAn RF field engineer arrived at a remote cell site in a mountainous reg
Read More -
Spectrum Monitoring Solutions for Broadcast Radio and Television Transmission Stations
August 17, 20261. When a 50 kW FM Transmitter Goes SilentA regional FM broadcaster serving roughly 2 million listeners lost its main transmitter
Read More -
Understanding Spectrum Analyzer Key Specifications: DANL, Phase Noise, TOI, and RBW
August 14, 20261. The Specification That Cost Two Weeks of DebuggingAn RF design team spent two weeks trying to measure the third harmonic of a 2
Read More -
Real-Time Spectrum Analyzer vs Traditional Swept Spectrum Analyzer: Which One Fits Modern RF Testing
August 13, 20261. The Purchase Decision That Engineers Keep Getting WrongA test equipment manager at a contract manufacturer ordered three tradit
Read More